Measuring range:
250 mbar to 250 bar
Output:
4...20 mA, 0...10 V, 0...5 V, 0,5...4,5 V
Medium temperature:
-25…100 °C
Accuracy:
0,5%
Measuring range:
100 mbar to 60 bar
Output:
4...20 mA, 0...5 V, 0...10 V, 0,5...4,5 V
Medium temperature:
-25...100 °C
Accuracy:
0,35%
Measuring range:
50 mbar to 40 bar
Output:
4...20 mA, 0...10 V
Medium temperature:
-25…100 °C (-25…125 °C)
Accuracy:
0,2%
Measuring range:
250 mbar to 100 bar
Output:
4...20 mA, 0,5...4,5 V, 0...5 V, 0...10 V
Medium temperature:
-25...100 °C
Accuracy:
0,5%
Measuring range:
100 mbar to 300 mbar
Output:
4...20 mA
Medium temperature:
-25...100 °C
Accuracy:
0,5%
Measuring range:
20 mbar to 60 bar
Output:
4...20 mA, 0...20 mA, 0...10 V
Medium temperature:
-40…100 °C (125 °C < 0,5h)
Accuracy:
0,2%
Measuring range:
40 mbar to 250 bar
Output:
4...20 mA, 0...10 V
Medium temperature:
-40…100 °C / -20…80 °C with ATEX
Accuracy:
0,2%
0,1% optional
Measuring range:
30 mbar to 40 bar
Output:
4...20 mA, 0...10 V
Medium temperature:
-40...100°C
Accuracy:
0,2%
0,1% optional
Measuring range:
30 mbar to 40 bar
Output:
4...20 mA, 0...10 V
Medium temperature:
-40...100°C
Accuracy:
0,2%
0,1% optional
Measuring range:
20 mbar to 60 bar
Output:
4...20 mA
Medium temperature:
-40…100 °C (125 °C < 0,5 h)
Accuracy:
0,2%
Measuring range:
30 mbar to 40 bar
Output:
4...20 mA, 0...10 V
Medium temperature:
-40...100°C
Accuracy:
0,2%
0,1% optional
Measuring range:
30 mbar to 40 bar
Output:
4...20 mA, 0...10 V
Medium temperature:
-40...100°C
Accuracy:
0,2%
0,1% optional
Measuring range:
40 mbar to 40 bar
Output:
4...20 mA, 0...10 V
Medium temperature:
-40…125 °C
Accuracy:
0,2%
Measuring range:
10 mbar to 60 bar
Output:
4...20 mA
Medium temperature:
-40…100 °C (125 °C < 0,5 h)
Accuracy:
0,2%
Measuring range:
250 mbar to 20 bar
2,5 mH2O to 200 mH2O
Output:
4...20 mA, 0,5...4,5 V, 0...5 V, 0...10 V
Medium temperature:
-25…80 °C
Accuracy:
0,5%
Measuring range:
40 mbar to 40 bar
Output:
4...20 mA
Medium temperature:
-25…100 °C
Accuracy:
0,3%
Measuring range:
250 mbar to 250 bar
Output:
4...20 mA, PNP switch output
Medium temperature:
-25...100 °C
Accuracy:
0,5%
Measuring range:
500 mbar to 50 bar
Output:
4...20 mA, PNP switch output
Medium temperature:
-25...100 °C
Accuracy:
0,5%
Measuring range:
500 mbar to 250 bar
Output:
4...20 mA, 0...20 mA, 0...10 V, PNP switch output
Medium temperature:
-25…100 °C
Accuracy:
0,5%
Measuring range:
25 mbar to 40 bar
Output:
4...20 mA, 0...20 mA, 0...10 V, PNP switch output
Medium temperature:
-25…100 °C
Accuracy:
0,5%
Measuring range:
25 mbar to 60 bar
Output:
4...20 mA, 0...20 mA, 0...10 V, PNP switch output
Medium temperature:
-25...100 °C
Accuracy:
0,5%
Measuring range:
250 mbar to 250 bar
Output:
4...20 mA, 0...20 mA, 0...10 V, PNP switch output
Medium temperature:
-25…100 °C
Accuracy:
0,5%
Measuring range:
50 mbar to 60 bar
-20 to 100 °C
Output:
4...20 mA, 0...20 mA, 0...10 V, PNP switch output
Medium temperature:
-20...100 °C
Accuracy:
0,5%
Measuring range:
25 mbar to 250 bar
Output:
4...20 mA, 0...20 mA, 0...10 V, Potential-free switch contact
Medium temperature:
-40…100 °C (125°C < 0,5 h)
Accuracy:
0,2%
Measuring range:
50 mbar to 20 bar
Output:
4...20 mA, 0...10 V
Medium temperature:
-25...120 °C, (Silicone oil filling)
Accuracy:
0,2%
Measuring range:
50 mbar to 20 bar
Output:
4...20 mA, 0...10 V
Medium temperature:
-25...120 °C, (Silicone oil filling)
Accuracy:
0,2%