Measuring ranges | Smallest measuring range: 0…50 mbar |
| Largest measuring range: 0…20 bar |
| Negative pressure measuring range: up to -20 bar |
Analog output | 4…20 mA, 2-wires |
| 0…10 V, 3-wires |
Power supply | 20 mA output: 9…30 V DC |
| 10 V output: 15…30 V DC |
Accuracy | ≤ ± 0,2 % FS @ 25 °C |
Long term stability | ≤ ± 0,1 % FS / Year |
Static pressure influence | ≤ ± 0,1 % FS/ 10 bar |
Hysteresis | ≤ ± 0,05 % FS |
Response time | 200 ms - others on request |
Swich-on time | < 1 s |
Temperature coefficient | Zero: ≤ ± 0,02 % FS / Kelvin |
| Span: ≤ ± 0,02 % FS / Kelvin |
Medium temperature | -25…120 °C |
Surrounding temperature | -25…85 °C |
Storage temperature | -40…85 °C |
Short-circuit resistance | Permanent |
Reverse polarity protection | Protection against reverse polarity, but no function |
Electromagnetic compatibility | Interference emissions and immunity acc. to EN 61326 |
Wetted materials | Process connection: Stainless steel 1.4404 |
| Sensor: Stainless steel 1.4404 with silicone oil filling |
Protection type | IP 67 |
Weight | Approx. 650 g |